Chapter 4: Powering On the Chassis
92
5. Secure the wire with the nut and washer removed in step 2, and an 8
mm wrench, as shown in Figure 60.
Allied Telesis recommends tightening the nut and washer to 26 inch-
lbs.
Figure 60. Securing the Bare Grounding Wire to the Grounding Post
6. After connecting the grounding wire, go to “Choosing a Method for
Attaching the Power Wires” on page 93.