107
Additional Maximum Power Reduction (A-MPR) (6.2.4) 3.1.33.
Because there are no test parameters supporting Additional Maximum Power Reduction tests and Additional
Spectrum Emission Mask tests, select the basic parameter (TX1 - Max. Power (QPSK/FullRB)) and set parameters
and standard values required for the test individually.
This chapter describes UL measurement examples where (Modulation, RB) are (QPSK, PartialRB), (QPSK, FullRB),
(16QAM, PartialRB) or(16QAM, FullRB) when additionalSpectrumEmission is NS_03 and Test Frequency is Mid range.
1. Execute BAND 2 to set Operating Band to 2.
2. Execute PWR_AVG 20 to set the average count of Power Measurement to 20 times.
3. Execute SEM_AVG 20 to set the average count of Spectrum Emission Mask to 20 times.
4. Execute TESTPRM TX_MAXPWR_Q_F to set Test parameter to TX1 - Max. Power (QPSK/FullRB).
5. Execute ALLMEASITEMS_OFF to set all fundamental measurement items to OFF.
6. Execute PWR_MEAS ON to set Power measurement to ON.
7. Execute SEM_MEAS ON to set Spectrum Emission Mask measurement to ON.
8. Execute SIB2_NS NS_03 to set additionalSpectrumEmission to NS_03.
[(QPSK, PartialRB) measurements]
9. Execute ULRMC_MOD QPSK to set UL RMC modulation to QPSK.
10. Execute ULRMC_RB 8 to set UL RB number to 8.
11. Execute ULRB_POS MIN to set UL RB Position to Min (#0).
12. Execute TP_MPR1_UL 25.7 to set TX Power measurement Pass/Fail upper limit to 25.7 dBm.
13. Execute TP_MPR1_LL 19.3 to set TX Power measurement Pass/Fail lower limit 19.3 dBm.
14. Execute SWP to measure the power.
15. Execute POWER? AVG to read the Tx Power measurement result.
16. Execute POWERPASS? to check the measurement result is PASS.
17. Execute SEMPASS? to check the SEM result is PASS.
18. Execute ULRB_POS MAX to set UL RB Position to Max (#max).
19. Execute step 14 to 17.
20. Execute ULRMC_RB 6 to set UL RB number to 6.
21. Execute ULRB_POS MIN to set UL RB Position to Min (#0).
22. Execute TP_MPR1_UL 25.7 to set TX Power measurement Pass/Fail upper limit to 25.7 dBm.
23. Execute TP_MPR1_LL 20.3 to set TX Power measurement Pass/Fail lower limit 20.3 dBm.
24. Execute step 14 to 17.
25. Execute ULRB_POS MAX to set UL RB Position to Max (#max).
26. Execute steps 14 to 17.
[(QPSK, FullRB) measurements]
27. Execute ULRMC_RB 25 to set UL RB number to 25.
28. Execute TP_MPR1_UL 25.7 to set TX Power measurement Pass/Fail upper limit to 25.7 dBm.
29. Execute TP_MPR1_LL 18.33 to set TX Power measurement Pass/Fail lower limit to 18.3 dBm.
30. Execute steps 14 to 17.
[(16QAM, PartialRB) measurements]
31. Execute ULRMC_MOD 16QAM to set UL RMC modulation method to 16QAM.
32. Execute ULRMC_RB 8 to set UL RB number to 8.
33. Execute ULRB_POS MIN to set UL RB Position to Min (#0).
34. Execute TP_MPR1_UL 25.7 to set TX Power measurement Pass/Fail upper limit to 25.7 dBm.
35. Execute TP_MPR1_LL 18.3 to set TX Power measurement Pass/Fail lower limit to 18.3 dBm.
36. Execute steps 14 to 17.
37. Execute ULRB_POS MAX to set UL RB Position to Max (#max).
38. Execute steps 14 to 17.