103
Spectrum Emission Mask for Multi-Cluster PUSCH (6.6.2.1_1) 3.1.29.
This chapter describes measurement examples for the following conditions.
First example: Channel Bandwidth = 20 MHz, UL Modulation is 16QAM,
UL Number of RB and Starting RB of Cluster1 is 4,0 respectively and
UL Number of RB and Starting RB of Cluster2 is 4,96 respectively.
Second example: Channel Bandwidth = 20 MHz, UL Modulation is 16QAM,
UL Number of RB and Starting RB of Cluster1 is 92,0 respectively and
UL Number of RB and Starting RB of Cluster2 is 4,96 respectively.
[Pass/Fail evaluation limits value setting]
1. Execute SEM_AVG 20 to set the average count of Spectrum Emission Mask to 20 times.
2. Execute TP_SEM5MHZ_1 -13.5 to set the Pass/Fail judgment of Spectrum Emission Mask Frequency Range
0 - 1 MHz.
3. Execute TP_SEM5MHZ_2 -8.5 to set the Pass/Fail judgment of Spectrum Emission Mask Frequency Range 1
- 5 MHz.
4. Execute TP_SEM5MHZ_3 -11.5 to set the Pass/Fail judgment of Spectrum Emission Mask Frequency Range
5 - 6 MHz.
5. Execute TP_SEM5MHZ_4 -23.5 to set the Pass/Fail judgment of Spectrum Emission Mask Frequency Range
6 - 10 MHz.
[(16QAM, PartialRB) measurements for first example]
6. Execute TESTPRM TX_MAXPWR_16_P to set Test Parameter to TX1 - Max. Power (16QAM/PartialRB)).
7. Execute CHCONFIG PUSCH_MULTI to set Common Parameter - RMC Configuration to PUSCH(Multi
Cluster).
8. Execute ULRB_MULTI 4,0,4,96 to set Common Parameter - UL RMC - 1
st
PUSCH Number of RB to 4, 1
st
PUSCH Starting RB to 0, 2
nd
PUSCH Number of RB to 4, and 2
nd
PUSCH Starting RB to 96.
9. Execute SWP to measure Spectrum Emission Mask.
10. Execute SEMPASS? to check that the SEM Pass/Fail judgment is Pass.
[(16QAM, PartialRB) measurements for second example]
11. Execute ULRB_MULTI 92,0,4,96 to set Common Parameter - UL RMC - 1
st
PUSCH Number of RB to 92, 1
st
PUSCH Starting RB to 0, 2
nd
PUSCH Number of RB to 4, and 2
nd
PUSCH Starting RB to 96.
12. Execute steps 9 and 10.
NOTE 1: The Pass/Fail evaluation value is initialized as described in TS36.521-1 6.6.2.1.5, 6.6.2.2.5 and used when
the Carrier Frequency is 3 GHz or less. When the Carrier Frequency exceeds 3 GHz, set:
TP_SEM**MHZ_1
TP_SEM**MHZ_2
TP_SEM**MHZ_3
TP_SEM**MHZ_4
as described in TS36.521-1 6.6.2.1.5, 6.6.2.2.5. (** = 1.4, 3, 5, 10, 15, 20).
For the Pass/Fail evaluation values, refer to chapter 3.7.4 Test Parameter Limit in the operation manual.