54
Changing DL/UL RB Allocation and MCS Index of each CCs 2.2.8.
This chapter describes a setting example when Channel Bandwidth is 10 MHz.
2.2.8.1. MT8820C
1. Changing PCC DL RB Allocation and MCS Indexes
1. [PCC] Execute DLRMC_RB 25 to set Common Parameter - DL RMC - Number of RB to 25.
2. [PCC] Execute DLIMCS1 5 to set Common Parameter - DL RMC - MCS Index 1 to 5.
3. [PCC] Execute DLIMCS2 6 to set Common Parameter - DL RMC - MCS Index 2 to 6.
4. [PCC] Execute DLIMCS3 7 to set Common Parameter - DL RMC - MCS Index 3 to 7.
<When TDD CA>
5. [PCC] Execute DLIMCS4 8 to set Common Parameter - DL RMC - MCS Index 4 to 8.
2. Changing SCC-1 DL RB Allocation and MCS Indexes
1. [PCC] Execute DLRMC_RB_SCC1 25 to set Call Processing Parameter - Carrier aggregation SCC-1 - DL RMC
- Number of RB to 25.
2. [PCC] Execute DLIMCS1_SCC1 5 to set Call Processing Parameter - Carrier aggregation SCC-1 - DL RMC -
MCS Index 1 to 5.
3. [PCC] Execute DLIMCS2_SCC1 6 to set Call Processing Parameter - Carrier aggregation SCC-1 - DL RMC -
MCS Index 2 to 6.
4. [PCC] Execute DLIMCS3_SCC1 7 to set Call Processing Parameter - Carrier aggregation SCC-1 - DL RMC -
MCS Index 3 to 7.
5. [SCC-1] Execute DLRMC_RB 25 to set Common Parameter - DL RMC - Number of RB to 25.
6. [SCC-1] Execute DLIMCS1 5 to set Common Parameter - DL RMC - MCS Index 1 to 5.
7. [SCC-1] Execute DLIMCS2 6 to set Common Parameter - DL RMC - MCS Index 2 to 6.
8. [SCC-1] Execute DLIMCS3 7 to set Common Parameter - DL RMC - MCS Index 3 to 7.
<When TDD CA>
9. [PCC] Execute DLIMCS4_SCC1 8 to set Call Processing Parameter - Carrier aggregation SCC-1 - DL RMC -
MCS Index 4 to 8.
10. [SCC-1] Execute DLIMCS4 8 to set Common Parameter - DL RMC - MCS Index 4 to 8.
3. Changing PCC UL RB Allocation and MCS Index
1. [PCC] Execute ULRMC_RB 20 to set Common Parameter - UL RMC - Number of RB to 20.
2. [PCC] Execute ULRB_START 5 to set Common Parameter - UL RMC - Starting RB to 5.
3. [PCC] Execute ULIMCS 6 to set Common Parameter - UL RMC - MCS Index to 6.
<When DL CA without UL CA>
4. [SCC-1] Execute ULRMC_RB_PCC 20 to set Call Processing Parameter - Carrier aggregation PCC - UL RMC -
Number of RB to 20.
5. [SCC-1] Execute ULRB_START_PCC 5 to set Call Processing Parameter – Carrier aggregation PCC - UL RMC
- Starting RB to 5.
6. [SCC-1] Execute ULIMCS_PCC 6 to set Call Processing Parameter - Carrier aggregation PCC - UL RMC -
MCS Index to 6.
4. Changing SCC-1 UL RB Allocation and MCS Index
1. [SCC-1] Execute ULRMC_RB 20 to set Common Parameter - UL RMC - Number of RB to 20.
2. [SCC-1] Execute ULRB_START 5 to set Common Parameter - UL RMC - Starting RB to 5.
3. [SCC-1] Execute ULIMCS 6 to set Common Parameter - UL RMC - MCS Index to 6.