64
Location Registration 2.3.4.
This performs UE location registration after setting the initial conditions (2.3.3).
2.3.4.1. MT8820C
1. Connect the UE and MT8820C.
2. [SCC-1/2] Execute LVL OFF to set SCC-1/2 output to Off.
3. [PCC] Execute CALLSO to clear the call processing status.
4. [PCC] Execute CALLSTAT? to query the call processing status is 1 (= idle).
5. Turn on the UE power.
6. [PCC] Execute CALLSTAT? to query the call processing status is 2 (= Idle(Regist)).
(If not 2 (= Idle(Regist)), repeat step 6.)
7. [SCC-1/2] Execute LVL ON to set SCC-1/2 output to On.
2.3.4.2. MT8821C
1. Connect the UE and MT8821C.
2. Execute CALLPROC ON to set Common Parameter - Call processing to ON.
3. Execute CALLSO to clear call processing status.
4. Execute CALLSTAT? to confirm the call processing status is 1 (= Idle).
5. Turn on the UE power.
6. Execute CALLSTAT? to confirm the call processing status is 2 (= Idle (Regist)).
Repeat step 6 when the checked status is not 2 (= Idle (Regist)).
Test Mode Connection and Disconnection 2.3.5.
Refer to chapter 2.1.4.