129
TX Measurements for Intra-band Contiguous CA 3.3.2.
This chapter explains the test procedure for Intra–band Contiguous CA measurement specified in 3GPP TS 36.521–
1.
Not all Intra–band Contiguous CA measurements are supported by MT8820C. Refer to Table 3.3–1 for the list of
supported measurement items.
Additionally, the MT8820C has the following limitations for Intra–band contiguous CA measurement.
Supports test execution through remote commands only.
Certain measurement items require manual computation of results.
Does not support Pass/Fail judgement for some measurement items, requiring user to manually
determine whether measurement results is Pass or Fail.
3.3.2.1. UE Maximum Output Power for CA (intra-band contiguous DL CA and UL CA) (6.2.2A.1)
3.3.2.1.1. MT8820C
This measurement item is not supported by the MT8820C.
Refere to Table 3.3-1.