149
Reference sensitivity level for CA (inter-band DL CA without UL CA) (7.3A.3) 3.4.3.
This measurement can be performed using the same procedure as in Chapter 3.4.1 by substituting the following
steps.
10. Execute DLCHAN 6075,300 to set Common Parameter – UL and DL Channel for PCC to 24075 and 6075,
and switch PCC and SCC Channel.
(This example is for Band1 and 19.)
11. Execute steps 1 to 7.
NOTE 1: Since PCC/SCC1 UL RMC – Number of RB depends on the Operation Band, set the value in
TS36.521–1 Table 7.3A.2.4.1–1.
NOTE 2: When the test case is 7.3A.3, perform step 6 to locate UL RMC – Number of RB as close as
possible to the DL as described in TS36.521–1 Table 7.3A.3.5–2 NOTE 4.
NOTE 3: When the test case is 7.3A.3, perform step 6 to locate UL RMC – Number of RB as close as
possible to the SCC DL as described in TS36.521–1 Table 7.3A.3.5–2 NOTE 1. When Band
Combination is 4A–17A, execute the following as described in TS36.521–1 Table 7.3A.3.5–2 NOTE
3.
For Channel Bandwidth 5 MHz: ULRB_START 9
For Channel Bandwidth 10 MHz: ULRB_START 17
Reference sensitivity level for CA (intra-band non-contiguous DL CA without UL CA) 3.4.4.
(7.3A.4)
Refer to chapter 3.4.1.
NOTE 1: Since PCC/SCC1 UL RMC – Number of RB depends on the Operation Band, set the value in
TS36.521–1 Table 7.3A.4.4.1–1.
NOTE 2: When the test case is 7.3A.4, perform step 6 to locate UL RMC - Number of RB as close as
possible to the DL as described in TS36.521–1 Table 7.3A.4.5–2 NOTE 4.