192
Figure 5.1.5.1-7 Throughput Measurement Result for UE Category 4 at Fundamental Measurement Parameter
Screen (MT8821C)
5.1.5.2. IPv6
This measurement can be performed using the same settings as in Chapter 5.1.5.1, by substituting the following
steps.
4. Open Command Prompt at the client PC and run the “ipconfig” command. As shown at the following
Command Prompt screen, the IPv6 address of the UE starts with the prefix 2001 and has a different
Interface ID from the Local Link address.
NOTES:
Interface ID specifies the least-significant 64 bits of the IPv6 address.
The IP address starting with 2001::xxxx:xxxx:xxxx:xxxx at the Command Prompt screen shown below, is
called the global address. On the other hand, the IP address starting with fe80::xxxx:xxxx:xxxx:xxxx is
called the local link address.
A UE not supporting automatic IPv6 address assignment uses the IP address set at IPv6Client IP Address
of the MT8821C.