[Procedure using Remote Commands]
1. Execute PRESET to set default parameter.
2. Execute CALLPROC ON to set Common Parameter - Call Processing to On.
3. Execute BANDWIDTH 20MHZ to set Common Parameter Frequency - Channel Bandwidth to 20 MHz.
4. Execute DLCHAN 300 to set Common Parameter - Frequency - UL Channel and DL Channel to 18300 and
300.
5. Execute CHCODING PACKET_DL_CA_PCC to set Common Parameter - Signal - Channel Coding to Packet
(DL CA).
6. Execute ANTCONFIG OPEN_LOOP to set Common Parameter - Signal - Antenna Configuration to
2x2MIMO (Open Loop).
7. Execute DLSCC 1 to set Call Processing Parameter - Carrier Aggregation - Number of DL SCC to 1.
8. Execute OLVL_EPRE -70.0 to set Common Parameter - Level - Output Level(EPRE) to 70.0 dBm/15 kHz.
9. Execute ULRMC_RB 100 to set Common Parameter - UL RMC - Number of RB to 100.
10. Execute ULIMCS 23 to set Common Parameter - UL RMC - MCS Index to 23.
11. Execute DLRB 100,0 to set Common Parameter - DL RMC - Number of RB to 100, and Common Parameter
- DL RMC - Starting RB to 0.
12. Execute DLIMCS1 28, DLIMCS2 28 and DLIMCS3 28 to set All of Common Parameter - DL RMC - MCS
Index1/2/3 to 28.
13. Execute BANDWIDTH_SCC1 20MHZ to set Common Parameter - SCC1 - Channel Bandwidth to 20 MHz.
14. Execute DLCHAN_SCC1 498 to set Common Parameter - SCC1 - DL Channel to 498.
15. Execute OLVL_EPRE_SCC1 -70.0 to set Common Parameter - SCC-1 - Output Level(EPRE) to 70.0
dBm/15kHz.
16. Execute DLRB_SCC1 100,0 to set Common Parameter - SCC1 - DL RMC - Number of RB to 100, and
Common Parameter - SCC1 - DL RMC - Starting RB to 0.
17. Execute DLIMCS1_SCC1 28, DLIMCS2_SCC1 28 and DLIMCS3_SCC1 28 to set All of Common Parameter -
SCC1 - DL RMC - MCS Index1/2/3 to 28.
18. Execute SERVERIP 192,168,20,10 to set Call Processing Parameter - Packet - Server IP Address to
192.168.20.10.
19. Execute CLIENTIP 192,168,20,11 to set Call Processing Parameter - Packet - Client IP Address 1 to
192.168.20.11.
20. Execute CLIENTIP2 192,168,20,12 to set Call Processing Parameter - Packet - Client IP Address 2 to
192.168.20.12.
21. Execute TFTIPV4 192,168,20,100 to set Call Processing Parameter - Packet - TFT Remote IPv4 Address to
192.168.20.100.
22. Execute TPUT_MEAS ON to set Fundamental Measurement Parameter - Throughput Measurement to
On.