241
6.2.5.6. Intra-Frequency Cell Reselection
1 [IntraFreq] Execute CELLID 100 to set Cell ID to 100.
2 [IntraFreq] Execute TAC 000A to set TAC to 000A.
3 [IntraFreq] Execute LVL OFF to set Output Level to Off.
4 [LTE] Execute OLVL_EPRE -50.0 to set Output Level (EPRE) to 50.0 (dBm/15 kHz).
5 [LTE] Execute QRXLEVMIN_SIB1 -70 to set Qrxlevmin (SIB1) to 70 (140 dB).
6 [LTE] Execute SINTRA -1 to set s-IntraSearch to Off (∞ dB).
7 [LTE] Execute NCAINTRAFREQ 1,100 to set the leftmost Intra Frequency Cell - Cell ID to 100.
8 [LTE] Execute NCAINTRAQOFFSET 0 to set Intra Frequency Cell - q-OffsetCell to 0 dB.
9 [LTE] Turn on the UE power and perform location registration (2.1.3).
10 [IntraFreq] Execute LVL ON to set Output Level to On.
11 [IntraFreq] Execute OLVL_EPRE -60.0 to set Output Level (EPRE) to 60.0 (dBm/15 kHz).
12 [LTE] Execute OLVL_EPRE -70.0 to set Output Level (EPRE) to 70.0 (dBm/15 kHz) and wait a few seconds.
13 [IntraFreq] Execute CALLSTAT? and check that the call processing static status is 2(= Idle (Regist)).