30
Item
Comment
MT8820C
MT8821C
Non-Call
Processing*
1
Call Processing
Non-Call
Processing*
1
Call Processing
7.7A.3
Spurious response for CA (inter-band DL CA
without UL CA)
12C/13C-021
Requires External
Equipment
X
√*
2
X
√*
2
7.7A.4
Spurious response for CA (intra-band
non-contiguous DL CA without UL CA)
12C/13C-021
Requires External
Equipment
X
√*
2
X
√*
2
7.8
Intermodulation characteristics
7.8.1
Wide band Intermodulation
Requires External
Equipment
√*
2,
*
4
√*
2
√*
2,
*
4
√*
2
7.8.1A
Wide band Intermodulation for CA
7.8.1A.1
Wide band Intermodulation for CA (Intra-band
Contiguous DL CA and UL CA)
12C/13C-022
Requires External
Equipment
X
√*
2
X
√*
2
7.8.1A.2
Wide band Intermodulation for CA (Intra-band
Contiguous DL CA without UL CA)
12C/13C--021
Requires External
Equipment
X
√*
2
X
√*
2
7.8.1A.3
Wide band Intermodulation for CA (Inter-band DL
CA without UL CA)
12C/13C--021
Requires External
Equipment
X
√*
2
X
√*
2
7.8.2
Void
7.9
Spurious emissions
Requires External
Equipment
X
X
7.10A
Receiver image for CA*
6
√√: Supported | √: Requires external equipment (SPA or SG) | : Measure by SPA | : Future Support | X: No Support
*1: Non-Call Processing does not support call processing function. In addition, because Loop Back and UL Power Control of payload data cannot be controlled, UEs must output
signals matching test conditions.
*2: This application note does not explain measurement procedures for appropriate test items.
*3: Supports measurements only (broadcast information is fixed).
*4: Outputs DL RMC defined from TS 36.521-1 Annex A Table A.3.2-1 to Table A.3.2-4 in fixed pattern (ARB).
Throughput measurements supported at UE side.
*5: 3GPP TS36.521-1 7.3A.4, 7.5A.3 test description are not yet defined.
*6: TS 36.101 [2] clause 7.10.1A specifies minimum requirements for receiver image for CA but recommends that these requirements do not need to be tested.
*7: MX882012C/13C-022 option does not support Intra-band contiguous DL CA and UL CA. MT882112C/13C support this test item.