SETUP "BASIC SETTINGS"
4B - GUIDED SETUP PROCEDURE FOR MACHINES WITH TOWED / 3-POINT HITCH IMPLEMENT
- From the "Home" page press F8.
- Select Implement (Fig. 54) and press OK.
Fig. 54
Implement > Start (Fig. 55)
- Delta 80 guides you through the setup procedure: follow all suggested steps and select required
options.
OK: next step ESC: previous step.
- When message
Press Ok to confirm selected settings is displayed, setup is completed.
Press OK.
- Press
ESC and return to the Settings menu.
- Now select
Tractor to start guided setup procedure as shown in Fig. 58.
Fig. 55 Fig. 56
OK Next step
ESC Previous step
Fig. 57
BASIC IMPLEMENT SETTINGS
• IMPLEMENT TYPE
Sprayer (Seletron): system with Seletron valves.
Sprayer (Electrovalves): system with electric-activated valves - with gearmotor.
• MAIN VALVE
Main control valve installed on the control unit:
None
2 ways
(drain valve)
3 ways (main valve)
• SPRAYING SPOT TYPE
Seletron type: single, twin or fourfold
• FLOWRATE REFERENCE SENSOR
Device used to calculate owrate:
Flowmeter
Pressure sensor
: measured pressure is used to calculate application rate.
Both: within the working limits the computer uses the owmeter, otherwise it uses the pressure sensor, ONLY if properly congured.
• TERMINAL NOZZLES
None
"Buffer zone" nozzles
: use switch panel to select nozzle to be used at "Buffer zone", see par. 12.2.1 "Buffer Zone" function enabled on page 74.
• TANK LEVEL SOURCE
Device used to read tank level:
Manual: no device connected
Filling flowmeter
Tank level sensor
CONTINUES
Par.
7. 4
Conrm access
or data change
Exit the function or
data change
Delete
selected
character
Scroll
(LEFT /
RIGHT)
Data
increase /
decrease
Scroll
(UP /
DOWN)
Enter
selected
character