AX-4030
1-19
AUTION MAX AX-4030 OPERATING MANUAL
Install the instrument in a place not exposed to direct sunlight, condensation
or wind. These factors may cause incorrect measurement results, as well as
deformation of or damage to the instrument.
Apply the correct voltage (100 to 240 V AC) and frequency (50/60 Hz) to the
instrument. The wrong voltage and frequency may result in fire or damage to the
instrument and consequently lead to personal injury.
Use the power cord that came with the instrument for the electrical connection to
avoid electric shock and fire.
Connect the instrument’s power cord directly to a single outlet, without using an
extension cord or power tap. The maximum power supply for the instrument is
150 VA.
Use the specified RS-232C cross cable to connect an external device to the 9-pin
data output terminal of the instrument, to avoid electric shock and fire. For more
information, contact your distributor.
Use the specified Ethernet cable to connect an external device to the Ethernet
terminal that is provided when the optional Ethernet board is installed in the
instrument. Use of other cables may cause electric shock or fire. For more
information, contact your distributor.
The START (1) and STOCK (2) terminals are used to connect optional joining
unit A or an expansion sampler. Connecting to other devices may cause damage
to the instrument. For the installation of these optional parts or precautions
on operating them, contact your distributor. Install optional parts under the
supervision of a serviceperson. Confirm operating precautions with the
serviceperson ahead of use.
DO NOT disassemble the instrument unless required for installation. DO NOT
modify the instrument. Disassembly and modification of the instrument may
result in exposure to pathogenic microbes or cause fire or damage to the
instrument and consequently lead to personal injury.
If you need to disassemble the instrument after use, wear protective gloves to
prevent exposure to pathogenic microbes.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arkray AUTION MAX AX-4030 and is the answer not in the manual?

Arkray AUTION MAX AX-4030 Specifications

General IconGeneral
BrandArkray
ModelAUTION MAX AX-4030
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals