Item Description
Severity One of the following codes (from highest to lowest severity):
M—(major) indicates that a fatal switch error has occurred.
E—(error) indicates that an error condition occurred on the switch.
W—(warning) indicates that a switch service has behaved unexpectedly.I—(information)
provides information on normal switch operation.
D—(debug) is reserved for HPE internal diagnostic information.
Date The date in the format mm/dd/yy when an entry is recorded in the log.
Time The time in the format hh:mm:ss when an entry is recorded in the log.
Event number The number assigned to an event. You can turn event numbering on and off with the [no]
log-number command.
System module The internal module (such as "ports:" for port manager) that generated a log entry. If VLANs
are configured, a VLAN name also appears for an event that is specific to an individual
VLAN.
Event message A brief description of the operating event.
Table 27: Event Log system modules
System module Description Documented in HPE Switch
hardware/software guide
802.1x 802.1X authentication: Provides
access control on a per-client or
per-port basis:
• Client-level security that allows
LAN access to 802.1X clients
(up to 32 per port) with valid user
credentials
• Port-level security that allows
LAN access only on ports on
which a single 802.1X-capable
client (supplicant) has entered
valid RADIUS user credentials
Access Security Guide
addrmgr Address Table Manager: Manages
MAC addresses that the switch has
learned and are stored in the
switch's address table.
Management and Configuration
Guide
Table Continued
Chapter 16 Troubleshooting 331