SIP User's Manual 136 Document #: LTRT-65415
MediaPack Series
Notes:
Several rows with the same NPI-TON or Phone-Context are allowed. In
such a scenario, a Tel-to-IP call uses the first match.
You can also configure the Phone Context table using the ini file table
parameter PhoneContext (see ''Number Manipulation and Routing
Parameters'' on page 474).
Table 3-23: Phone-Context Parameters Description
Parameter Description
Add Phone Context As Prefix
[AddPhoneContextAsPrefix]
Determines whether the received Phone-Context parameter is added
as a prefix to the outgoing Called and Calling numbers.
[0] Disable (default)
[1] Enable
NPI Select the Number Plan assigned to this entry.
[0] Unknown (default)
[1] E.164 Public
[9] Private
TON Select the Type of Number assigned to this entry.
If you selected Unknown as the NPI, you can select Unknown [0].
If you selected Private as the NPI, you can select one of the
following:
9 [0] Unknown
9 [1] Level 2 Regional
9 [2] Level 1 Regional
9 [3] PSTN Specific
9 [4] Level 0 Regional (Local)
If you selected E.164 Public as the NPI, you can select one of the
following:
9 [0] Unknown
9 [1] International
9 [2] National
9 [3] Network Specific
9 [4] Subscriber
9 [6] Abbreviated
Phone Context The Phone-Context SIP URI parameter.

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
ModelMediaPack MP-124
CategoryGateway
ProtocolsSIP, H.323, MGCP
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Fax SupportT.38
ManagementSNMP
SecurityTLS/SRTP
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-25 to 70°C
Humidity10% to 90%, non-condensing
Analog Ports24 FXS