EasyManuals Logo

AudioCodes MediaPack MP-124 User Manual

AudioCodes MediaPack MP-124
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #473 background imageLoading...
Page #473 background image
Version 6.2 473 February 2011
SIP User's Manual 10. Configuration Parameters Reference
Parameter Description
Web: Rings before
Detecting Caller ID
EMS: Rings Before Caller
ID
[RingsBeforeCallerID]
Determines the number of rings before the device starts detecting
Caller ID.
[0] 0 = Before first ring.
[1] 1 = After first ring (default).
[2] 2 = After second ring.
Note: This parameter is applicable only to FXO interfaces.
Web/EMS: Guard Time
Between Calls
[GuardTimeBetweenCalls]
Defines the time interval (in seconds) after a call has ended and a new
call can be accepted for IP-to-Tel (FXO) calls.
The valid range is 0 to 10. The default value is 1.
Notes:
Occasionally, after a call ends and on-hook is applied, a delay is
required before placing a new call (and performing off-hook). This is
necessary to prevent incorrect hook-flash detection or other glare
phenomena.
This parameter is applicable only to FXO interfaces.
10.12.10 FXS Parameters
The general FXS parameters are described in the table below.
Table 10-58: General FXS Parameters
Parameter Description
Web: FXS Coefficient Type
EMS: Country Coefficients
[FXSCountryCoefficients]
Determines the FXS line characteristics (AC and DC) according to USA
or Europe (TBR21) standards.
[66] Europe = TBR21
[70] USA = United States (default)
Note: For this parameter to take effect, a device reset is required.

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
ModelMediaPack MP-124
CategoryGateway
ProtocolsSIP, H.323, MGCP
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Fax SupportT.38
ManagementSNMP
SecurityTLS/SRTP
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-25 to 70°C
Humidity10% to 90%, non-condensing
Analog Ports24 FXS