Version 6.2 181 February 2011
SIP User's Manual 3. Web-Based Management
¾ To activate the Message Log:
1. Activate and configure the device's Syslog client.
2. Open the 'Message Log' page (Status & Diagnostics tab > System Status menu >
Message Log); the 'Message Log' page is displayed and the log is activated.
Figure 3-112: Message Log Page
The displayed logged messages are color coded as follows:
Yellow - fatal error message
Blue - recoverable error message (i.e., non-fatal error)
Black - notice message
3. To clear the page of Syslog messages, access the 'Message Log' page again (see
Step 2); the page is cleared and new messages begin appearing.
¾ To stop the Message Log:
Close the 'Message Log' page by accessing any another page in the Web interface.

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
ModelMediaPack MP-124
CategoryGateway
ProtocolsSIP, H.323, MGCP
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Fax SupportT.38
ManagementSNMP
SecurityTLS/SRTP
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-25 to 70°C
Humidity10% to 90%, non-condensing
Analog Ports24 FXS

Related product manuals