3.5.2.6 Viewing Registration Status
The 'Registration Status' page displays whether the device, its endpoints, SIP Accounts,
and BRI endpoints are registered to a SIP Registrar/Proxy server.
¾ To view Registration status:
Open the 'Registration Status' page (Status & Diagnostics tab > VoIP Status menu
> Registration Status).
Figure 3-120: Registration Status Page
Registered Per Gateway:
'YES' = registration is per device
'NO' = registration is not per device
Ports Registration Status:
'REGISTERED' = channel is registered
'NOT REGISTERED' = channel not registered
Accounts Registration Status: registration status based on the Accounts table
(configured in ''Configuring Account Table'' on page 113):
Group Type: type of served group - Hunt Group or IP Group
Group Name: name of the served group, if applicable
Status: indicates whether or not the group is registered ('Registered' or
'Unregistered')
Note: The registration mode (i.e., per device, endpoint, account. or no registration)
is configured in the 'Hunt Group Settings' table (see ''Configuring Hunt Group
Settings'' on page 126) or using the TrunkGroupSettings ini file parameter.

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
ModelMediaPack MP-124
CategoryGateway
ProtocolsSIP, H.323, MGCP
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Fax SupportT.38
ManagementSNMP
SecurityTLS/SRTP
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-25 to 70°C
Humidity10% to 90%, non-condensing
Analog Ports24 FXS

Related product manuals