EasyManuals Logo

AudioCodes MediaPack MP-124 User Manual

AudioCodes MediaPack MP-124
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #464 background imageLoading...
Page #464 background image
SIP User's Manual 464 Document #: LTRT-65415
MediaPack Series
Parameter Description
FXSPort_Last = end range of FXS ports.
SourcePrefix = prefix of the calling number.
DestinationPrefix = prefix of the called number.
PriorityIndex = index for Distinctive Ringing and Call
Waiting tones (default is 0):
9 Ringing tone index = index in the CPT file for playing
the ring tone.
9 Call Waiting tone index = priority index +
FirstCallWaitingToneID(*). For example, if you want to
select the Call Waiting tone defined in the CPT file at
Index #9, then you can enter 1 as the priority index
and the value 8 for FirstCallWaitingToneID. The
summation of these values equals 9, i.e., index #9.
For example, the configuration below plays the tone Index #3
to FXS ports 1 and 2 if the source number prefix of the
received call is 20.
ToneIndex 1 = 1, 2, 20*, , 3;
Notes:
You can define up to 50 indices.
This parameter is applicable only to FXS interfaces.
Typically, the Ringing and/or Call Waiting tone played is
indicated in the SIP Alert-Info header field of the received
INVITE message. If this header is not present, then the
tone played is according to the settings of this table.
For depicting a range of FXS ports, use the syntax x-y
(e.g., "1-4" for ports 1 through 4).
You can configure multiple entries with different source
and/or destination prefixes and tones for the same FXS
port.
10.12.7.2 Tone Detection Parameters
The signal tone detection parameters are described in the table below.
Table 10-54: Tone Detection Parameters
Parameter Description
EMS: DTMF Enable
[DTMFDetectorEnable]
Enables or disables the detection of DTMF signaling.
[0] = Disable
[1] = Enable (default)
EMS: MF R1 Enable
[MFR1DetectorEnable]
Enables or disables the detection of MF-R1 signaling.
[0] = Disable (default)
[1] = Enable
EMS: User Defined Tone Enable
[UserDefinedToneDetectorEnable]
Enables or disables the detection of User Defined Tones
signaling, applicable for Special Information Tone (SIT)
detection.
[0] = Disable (default)
[1] = Enable

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
ModelMediaPack MP-124
CategoryGateway
ProtocolsSIP, H.323, MGCP
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Fax SupportT.38
ManagementSNMP
SecurityTLS/SRTP
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-25 to 70°C
Humidity10% to 90%, non-condensing