EasyManua.ls Logo

AudioCodes MediaPack MP-124

AudioCodes MediaPack MP-124
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 6.2 209 February 2011
SIP User's Manual 5. EMS-Based Management
5. To end the PuTTY configuration session, type a full-stop (“.”) on an empty line; the
device responds with the following:
INI File replaced
6. To save the configuration to the non-volatile memory, type sar; the device reboots
with IPSec enabled.
5.8.2 Configuring EMS to Operate with a Pre-configured SNMPv3
System
The procedure below describes how to configure the device with a pre-configured
SNMPv3.
¾ To configure EMS to operate with a pre-configured SNMPv3 system:
1. In the MG Tree, select the required Region to which the device belongs, and then
right-click the device.
2. From the shortcut menu, choose Details; the 'MG Information' screen appears.
Figure 5-8: MG Information Screen
3. Select the SNMPv3 option, configure the SNMP fields, and then click OK.
4. Open the 'SNMPv3 Users' screen (Navigation pane > System > Management >
SNMP Frame > SNMPv3 Users tab).
5. From the SNMPv3 Users tab's drop-down list, choose Unit value; the 'SNMPv3
Users' table is refreshed with the values that you entered in Step 3.
6. Click the Save button; the EMS and the device are now synchronized.

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Related product manuals