SIP User's Manual 466 Document #: LTRT-65415
MediaPack Series
Parameter Description
Web: Analog TTX Voltage
Level
EMS: TTX Voltage Level
[AnalogTTXVoltageLevel
]
Determines the metering signal/pulse voltage level (TTX).
[0] 0V = 0 Vrms sinusoidal bursts
[1] 0.5V = 0.5 Vrms sinusoidal bursts (default)
[2] 1V = 1 Vrms sinusoidal bursts
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.
Web: Charge Codes Table
EMS: Charge Codes
[ChargeCode]
This ini file table parameter configures metering tones (and their time
intervals) that the device's FXS interface generates to the Tel side.
The format of this parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_Index = ChargeCode_EndTime1,
ChargeCode_PulseInterval1, ChargeCode_PulsesOnAnswer1,
ChargeCode_EndTime2, ChargeCode_PulseInterval2,
ChargeCode_PulsesOnAnswer2, ChargeCode_EndTime3,
ChargeCode_PulseInterval3, ChargeCode_PulsesOnAnswer3,
ChargeCode_EndTime4, ChargeCode_PulseInterval4,
ChargeCode_PulsesOnAnswer4;
[\ChargeCode]
Where,
EndTime = Period (1 - 4) end time.
PulseInterval = Period (1 - 4) pulse interval.
PulsesOnAnswer = Period (1 - 4) pulses on answer.
For example:
ChargeCode 1 = 7,30,1,14,20,2,20,15,1,0,60,1;
ChargeCode 2 = 5,60,1,14,20,1,0,60,1;
ChargeCode 3 = 0,60,1;
ChargeCode 0 = 6, 3, 1, 12, 2, 1, 18, 5, 2, 0, 2, 1;
Notes:
The parameter can include up to 25 indices (i.e., up to 25 different
metering rules can be defined).
This parameter is applicable only to FXS interfaces.
To associate a charge code to an outgoing Tel-to-IP call, use the
'Tel to IP Routing'.
To configure the Charge Codes table using the Web interface, see
''Configuring Charge Codes Table'' on page 151.
For an explanation on configuration using ini file table parameters,
see ''Configuring ini File Table Parameters'' on page 194.