1 Mk8 MM Overview, Specifications and Wiring
Mk8 MM Manual Page | 14
1.1.1 Mk8 MM Main Features
Fuel/Air ratio control
12.1” Full colour touch screen
120V or 230V standard operation 50/60Hz
Controls up to 5 servomotors and 2 variable speed drives (VSD/ VFD)
4 independent fuel programmes
Fully adjustable PID load control for temperature or pressure
Internal flame safeguard full flame supervision with self-check UV or IR
Dual flame scanner operation (IR and UV scanners)
Gas valve train leak supervision and high/low gas pressure monitoring
Air pressure proving and monitoring
128 lockouts, errors, alarms and warnings stored with date, time, phase and reset
1000 entry system log stored with date, time and status
Online diagnostics showing system electronics information
Single point change for adding, removing and adjusting fuel/air positions on fuel-air curve
Golden start position for optimum ignition position
Flue gas recirculation start position
Variable servomotor travel speed
Burner control safety times user selectable
External voltage/current load control and setpoint adjustment
Outside temperature compensation of boiler setpoint
Second setpoint and run times scheduling
Hand/auto/low flame hold firing modes
Various boiler load detectors available
Fuel flow metering capability instantaneous and totalised
Fuel flow feedback
Multi-burner capability with synchronised firing rate up to 10 MMs
4-20mA (0-20mA) / 0-10V (2-10V) input for external modulation
4-20mA (0-20mA) / 0-10V (2-10V) output confirming firing rate
Fully metered combustion control for commissioning based on equivalence ratio and excess air
Draft control to maintain stack pressure
Password protection of all safety related functions
Infra-red port for upload/download of commission data
15 First out annunciation inputs
4 fuel commission curves possible
24-hour history graphical information on MM when powered on
Custom boiler display configuration
Download / upload all commissioning data and controller settings from MM module to a PC via
Bluetooth or IR
System will sequence hot water boilers or steam boilers via lead/lag distribution
Fully adjustable user options within the system to tailor sequencing operation to the application
System control for isolation of valves or pumps (2 port valve operation)
Standby setpoint and warming for lag boilers via a standby pressure and timing sequence
Lead boiler and lag boiler warming modes selection
Return to pilot allows the main flame to turn off and the pilot flame can continue
Fully modulating feed water control with servomotor and VSD as well pump on/off
Capacitance probes for patented wave signature level detection
Water level alarms 2
nd
low, 1
st
low, high water and optional pre 1
st
low and pre-high water
Conductivity probe for auxiliary 2
nd
low alarm
Automatic bottom blowdown with time reduction for blowdown savings
Continuous modulating top blowdown control to maintain TDS level in water
Steam/ hot water flow metering to calculate flow rates based on temperature sensor
Direct Modbus communications from MM including remote setpoint and firing rate adjustment, burner
enable/disable (without DTI or intelligent boiler sequencing)
Fuel Changeover on the Fly (COF) which allows fuel change without turning off the burner

Table of Contents

Other manuals for AUTOFLAME Mk8 MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUTOFLAME Mk8 MM and is the answer not in the manual?

AUTOFLAME Mk8 MM Specifications

General IconGeneral
BrandAUTOFLAME
ModelMk8 MM
CategoryController
LanguageEnglish

Related product manuals