Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
Install and Cable the Cabinet
1-98Install and wire telephones and other equipment
1
The general steps to connect a telephone are:
1. Choose a device to connect such as a 302C1 Attendant Console.
2. Choose the port circuit pack and its carrier and slot number, such as
TN754C, Carrier A, Slot 06.
3. Choose a port circuit on the port circuit pack, such as Port 05.
4. Install cross-connect jumpers to wire the terminal to the port circuit pack.
See Figure 1-47. This pinout is for a 4-wire digital line circuit pack.
Figure 1-47. 302C1 to digital line circuit pack wiring
Figure Notes
1. 302C1 Attendant Console
2. 4-wire digital line circuit pack
3. -48 VDC from adjunct power
4. Ground from adjunct power
2
wir
RPY
12
1
39
14
40
15
2
3
6
7
8
TXT
TXR
PXT
PXR
TXT5
TXR5
PXT5
PXR5