Install and Cable the Cabinet
1-99Install and wire telephones and other equipment
1
Connect adjunct power
The400B2 adapter is convenient for connecting local -48 VDC power to a modular
plug. See Figure 1-48.
Figure 1-48. 400B2 adapter connecting to a modular plug
Adjunct power can be provided from the equipment room or equipment closet with
1145B power unit. The AUX connector (J1) on the processor interface cable can
provide power for 1 Attendant Console.
Adjunct power can be provided locally at the telephone or console by the 1151A or
1151A2 Power Supply.
Figure Notes
1. Surface-mounted information outlet
2. To individual power unit (such as 1151A
or 1151A2)
3. 400B2 adapter
4. To telephone
5. Destination service access point
(DSAP) power cord