Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
Intuity AUDIX Digital Networking
4-19Changing local machine information
4
6.Press F3 [Enter] to save the information.
The cursor returns to the command line, and the system displays the
following message:
Command Successfully Completed
.
7.Press
F3 [Cancel] to return to the command line.
8.Enter exit or another administrative command at the
enter command:
prompt.
Table 4-6. Field definitions; remote machine profile screen, page 2
Field Valid Input Description
Send to Non-
Administered
Recipients?
y= yes
n = no
Enter y if the system will attempt to deliver
messages to non-administered remote recipients.
Enter n if messages cannot be sent to
nonadministered recipients.
Updates:
In?
y= yes
n = no
Enter y if the local system will accept updated
database information from the remote system (the
Updates Out field must also be set to y on the local
Machine Profile screen).
Set to y only after testing the network end-to-end
during initial administration.
Updates:
Out?
y= yes
n = no
Enter y if the local system will send updated
database information to the remote system (the
Updates In field must also be set to y on the local
Machine Profile screen).
Set to y only after testing the network end-to-end
during initial administration.
Network
Turnaround
y= yes
n = no
If you are conducting an acceptance test, enter n.
After the acceptance tests, enter y if a network
connection that originated from this remote system
is allowed to turn around after the remote system
has sent all of its network data to the local system.
The local system may then return update
information, voice mail, and status on the same
connection. This feature reduces toll charges and
increases the efficiency of the system in networks
with more than 10 machines.
The Network Turnaround field must be set to y on
the local Machine Profile screen for this feature to
work between the local system and the remote
system.