Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
Recovery
D-2DEFINITY ONE or IP600 system level shutdown and restart
D
Table D-1. Shutdown and restart actions
Action Entry Originated by Action Notes
“reboot nice”
[campon]
command
line entry
from a bash
session
technician Shuts down all
applications with
campon to wait for
Intuity AUDIX users to
logoff. The system
restarts automatically.
Used for a system reboot
after changing a
Windows 2000 level
parameter that requires a
system reboot. This may
take an unacceptably
long time due to campon
of Intuity AUDIX logons.
“reboot
immediate”
command
line entry
from a bash
session
technician Shuts down all
applications without
waiting for Intuity
AUDIX users to log
off. The system
restarts automatically.
Used for a system reboot
with a guaranteed reboot
time of a few minutes.
This action does not wait
for Intuity AUDIX users to
be logged off from Intuity
AUDIX.
“shutdown
all”
[campon]
command
line entry
from a bash
session
technician Shuts down
application software
while leaving
Windows 2000 up. An
optional “campon”
option may be used to
wait for Intuity AUDIX
users to log off.
Used for system
upgrade. The campon
option may cause an
unacceptable wait time.
The “start all” command
can be used to restart the
application software.
“shutdown
audix”
[campon]
command
line entry
from a bash
session
technician Shuts down Intuity
AUDIX while leaving
DEFINITY and
Windows 2000 up. An
optional “campon”
option may be used to
wait for Intuity AUDIX
users to log off.
Used to shut down Intuity
AUDIX if the machine
name is changed. The
“start audix” command
can be used to restart
Intuity AUDIX. The
campon option may
cause an unacceptable
wait time.
“shutdown
system”
[campon]
command
line entry
from a bash
session
technician Shuts down the
system without
restarting it An
optional “campon”
options may by used
to wait for Intuity
AUDIX users to log
off. The system does
not restart
automatically.
Used to shut down the
system in preparation for
removing AC power or
removing the TN2314
Processor circuit pack.
The campon option may
cause an unacceptable
wait time.The system can
be restarted only by
removing and restoring
power or reseating the
TN2314.
Continued on next page