Loading...
Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
Recovery
D-3DEFINITY ONE or IP600 system level shutdown and restart
D
“delayed
shutdown”
button
web page
from a web
browser
technician/
customer
Wait for Intuity AUDIX
users to log of f
before starting a
system shutdown.
The system may or
may not restart
automatically,
depending on a
“restart” option.
Used to shut down the
system in preparation for
removing AC power or
removing the TN2314
Processor circuit pack
immediate
shutdown”
button
web page
from a web
browser
technician/
customer
Do not wait for Intuity
AUDIX users to log off
before starting a
system shutdown.
The system may or
may not restart
automatically,
depending on a
“restart” option.
Used to shut down the
system in preparation for
removing AC power or
removing the TN2314
Processor circuit pack
shutdown
button on the
faceplate of
the TN2314
processor
board
Faceplate of
the TN2314
processor
board
technician/
customer
Shut down the system
after closing all
applications. The
system will not restart
automatically.
Used to shut down the
system in preparation for
removing AC power or
removing the TN2314
Processor circuit pack.
The system can be
restarted only by
removing and restoring
power or reseating the
TN2314.
Detection of
the loss of
AC power by
the UPS
Wiring from
the UPS
Z3A2 alarm
adapter to
the Major
Alarm lead
on the
TN2314
Loss of AC
power for more
than 1 minute
Shut down the system
after closing all
applications. The
system will restart
automatically upon
restoration of AC
power.
Provides a graceful
shutdown when AC
power is lost for more
than 1 minute.
Table D-1. Shutdown and restart actions — Continued
Action Entry Originated by Action Notes

Table of Contents