7.2.3. Monthly maintenance
- Check Cooling unit (if present)
- Check the degree of protection of antifreeze liquid in water cooler (if present) (dependent on
season and minimum room temperature).
- Check the condenser of the radiator cooling unit.
- Check the torque of all mounting bolts, especially on the vibrator motors of the infeed shaker.
- Check the operation of all Emergency Stops & Laser Interlocks (if present)
7.2.4. Yearly maintenance
- Clean or replace the fi lter of the air pressure regulator (see 7.3).
- Replace Detection Belt +/- once a year (depending on product and machine confi guration)
(Procedure later in this chapter)
- Replace fl uorescent tubes in illumination units with new ones of the same type.
- Clean the condenser of the radiator cooling unit
- Check the general state of the bearing blocks of the detection belt (2 on belt drive drum, and - if
present - 2 on return shaft) and of the reference roller/background drum (2, if present).
(After 3000 hours of operation or every year.)
- Verify wear and tear and state of seals.
- Check greasing and replace grease if necessary.
(For more info, see greasing procedure later in this chapter.)
- Renew oil for drive drum motors of rollers and return system belts.
(After 10.000 hours or every 2 years)
(For more info, see manufacturer information in Attachments chapter)
- Renew oil and bearing grease of drive drum motor of detection belt.
(After 20.000 hours or every 4 years)
(For more info, see manufacturer information in Attachments chapter)
- Yearly preventive revision of small return axle (only for 1200 mm version of GENIUS Compact).
(Replace bearings or completely replace return axle assembly)
- If greased regularly (preferably after every cleaning of the machine) the bearings of the standard return
axle system (Ø 75 mm) may last 5 to 10 years without needing replacement.