5.4. Normalization
Attention: - Make sure the belt is running when taking a normalization!
- Belt surface must be clean and undamaged and no product may pass over
the belt while taking a new normalization.
- Be sure to take a new normalization for all camera’s after start-up, before
determining product settings or starting the sorting process.
- Always take into account the warm-up time for the lights and optics, (+/-30
min. after a longer stop), before taking a normalization.
- On top of this, it is advisable to take a new normalization every time the
system is halted and/or restarted.
Attention: - If something goes wrong with the New Normalization, the system will still
overwrite the Old Normalization. This means that any problems that occur
must be solved, and a new normalization must be taken successfully before
the sorting process can be started!
- If something keeps going wrong when taking the normalization, please note
the content of the error message and contact the BESTnv service department
To take a new normalization, use the Touchscreen on the control panel; the touchscreen program starts
automatically when the GENIUS Compact is started. The normalization procedure in operator level differs
from the procedure in expert level.