Chapter 5: Routine Operational Procedures
Operators & Maintenance Manual GENIUS Compact Version UK 0.1 © BESTnv
BESTnv Industrial Research BV, Marinus van Meelweg 20, 5657 EN, EINDHOVEN, THE NETHERLANDS
General tel. +31 (40) 292 2622 - Service tel. +31 (40) 292 2620 - Fax. +31 (40) 292 2633 - Email: service.BESTnv@bestnv.com
3. Standard Shutdown/Startup
Standard Shutdown Procedure
- For short periods of inactivity. Only the lighting, the moving parts and related machinery controlled by
the GENIUS Compact will be switched off. The rest of the sorter will still have current: Touchscreen
display and electronics will still be powered.
1. Switch Control Voltage button to Off (0) (see control panel: 7).
(Only when Product Line switch (8) is on manual.)
Standard Startup Procedure
- All accompanying machinery (Infeed shakers and/or return systems e.g.) controlled by the GENIUS
Compact will be switched on automatically as well.
Attention: - Even after a short shutdown period the lights and the optics may need a few
minutes to stabilize.
1. Activate Control Voltage button (see control panel: 7).
(Only when Product Line switch (8) is on manual.)
2. Activate other buttons on control panel (see control panel: 9-11).
- All accompanying machinery (Infeed shakers and/or return systems e.g.) controlled by the GENIUS
Compact will be switched on automatically.
3. Switch on all other related machinery (if present) not controlled by the sorter unit.
Remark: - When switching On the Control Voltage button, always make sure the
compressed air supply is activated. Without compressed air, continuously
activated air gun valves may remain unnoticed for a long period, overheat,
and short-circuit.