15-15
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Software Configuration Guide
OL-14127-08
Chapter 15 Configuring the 8-Port Channelized T1/E1 SPA
Configuration Examples
! Exit global configuration mode
!
Router(config)# exit
Facility Data Link Configuration Example
The following example configures Facility Data Link:
! Specify the controller and enter controller configuration mode
!
Router(config)# controller t1 2/0/0
!
! Specify the FDL specification
!
Router(config-controller)# fdl ansi
!
! Exit controller configuration mode and return to global configuration mode
!
Router(config-controller)# exit
!
! Exit global configuration mode
!
Router(config)# exit
Invert Data on the T1/E1 Interface Example
The following example inverts the data on the serial interface:
! Enter global configuration mode
!
Router# configure terminal
!
! Specify the serial interface and enter interface configuration mode
!
Router(config)# interface serial 2/1/3:0
!
! Configure invert data
!
Router(config-if)# invert data
!
! Exit interface configuration mode and return to global configuration mode
!
Router(config-if)# exit
!
! Exit global configuration mode
!
Router(config)# exit

Table of Contents

Other manuals for Cisco ASR 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1000 and is the answer not in the manual?

Cisco ASR 1000 Specifications

General IconGeneral
Operating SystemCisco IOS XE
Interfaces10 Gigabit Ethernet
Power SupplyAC or DC
Number of Total Expansion SlotsVaries by model
Management PortConsole
Redundant Power Supply SupportedYes
Width17.5 inches
MemoryVaries by model
StorageVaries by model
Dimensions (H x W x D)Varies by model
WeightVaries by model
Operating Temperature32°F to 104°F (0°C to 40°C)
Humidity5% to 95% non-condensing
MTBFVaries by model
RedundancyRedundant power supplies, fans, and route processors (depending on model)

Related product manuals