5
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Software Configuration Guide
OL-14127-08
Troubleshooting the SIP
Preparing for Online Insertion and Removal of the SIP and SPAs
0/1 SPA-8X1FE-TX-V2 ok 03:18:28
0/2 SPA-2XCT3/DS0 ok 03:18:19
1 ASR1000-SIP10 ok 03:19:46
1/0 SPA-2XOC3-POS ok 03:18:28
1/1 SPA-8XCHT1/E1 ok 03:18:28
1/2 SPA-2XT3/E3 ok 03:18:18
R0 ASR1000-RP1 ok, active 03:19:46
F0 ASR1000-ESP10 ok, active 03:19:46
P0 ASR1006-PWR-AC ok 03:19:14
P1 ASR1006-FAN ok 03:19:14
The following example shows the Cisco ASR 1000-SIP10 installed in slot 0 and Cisco ASR1000-SIP40
installed in slots 1,2,3, and 4 for the Cisco ASR 1013 Router:
Router#show platform
Chassis type: ASR1013
Slot Type State Insert time (ago)
--------- ------------------- --------------------- -----------------
0 ASR1000-SIP10 ok 1w0d
1 ASR1000-SIP40 ok 1w0d
1/1 SPA-5X1GE-V2 ok 1w0d
2 ASR1000-SIP40 ok 1w0d
2/1 SPA-1X10GE-L-V2 ok 1w0d
2/3 SPA-1X10GE-L-V2 ok 1w0d
3 ASR1000-SIP40 ok 1w0d
3/3 SPA-4XT3/E3 ok 1w0d
4 ASR1000-SIP40 ok 1w0d
4/2 SPA-5X1GE-V2 ok 1w0d
4/3 SPA-4XCT3/DS0 ok 1w0d
5 ASR1000-SIP40 ok 1w0d
R0 ASR1000-RP2 ok, active 1w0d
R1 ASR1000-RP2 ok, standby 1w0d
F0 ASR1000-ESP40 ok, active 1w0d
P0 ASR1013-PWR-AC ok 1w0d
P1 ASR1013-PWR-AC ps, fail 1w0d
P2 ASR1013-PWR-AC ok 1w0d
P3 ASR1013-PWR-AC ps, fail 1w0d
Slot CPLD Version Firmware Version
--------- ------------------- ---------------------------------------
0 00200800 15.0(1r)S
1 00200800 15.0(1r)S
2 00200800 15.0(1r)S
3 00200800 15.0(1r)S
4 00200800 15.0(1r)S
5 00200800 15.0(1r)S
R0 10021901 15.0(1r)S
R1 10021901 15.0(1r)S
F0 1001270D 15.0(1r)S
Preparing for Online Removal of a SPA
The Cisco ASR 1000 Series Routers support OIR of a SPA independently of removing the SIP. This
means that a SIP can remain installed in the Cisco Aggregation Services Router-1 with one SPA
remaining active, while you remove another SPA from one of the SIP subslots. If you are not planning
to immediately replace a SPA into the SIP, then be sure to install a blank filler plate in the subslot. The
SIP should always be fully installed with either functional SPAs or blank filler plates.
If you are planning to remove a SIP along with its SPAs, then you do not need to follow the instructions
in this section. To remove a SIP, see the