EasyManuals Logo

Cisco Catalyst 2950 Command Reference

Cisco Catalyst 2950
686 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #288 background imageLoading...
Page #288 background image
2-258
Catalyst 2950 and Catalyst 2955 Switch Command Reference
OL-10102-01
Chapter 2 Catalyst 2950 and 2955 Cisco IOS Commands
remote-span
remote-span
Use the remote-span VLAN configuration command to add the Remote Switched Port Analyzer
(RSPAN) feature to a VLAN. Use the no form of this command to remove the RSPAN feature from the
VLAN.
remote-span
no remote-span
This command is available only if your switch is running the enhanced software image (EI).
Syntax Description This command has no arguments or keywords.
Defaults No RSPAN VLANs are defined.
Command Modes VLAN configuration
Command History
Usage Guidelines When a VLAN is converted from a normal VLAN to an RSPAN VLAN (or the reverse), the VLAN is
first deleted and is then recreated with the new configuration. The RSPAN feature is propagated by
VLAN Trunking Protocol (VTP) for VLAN-IDs that are lower than 1005.
Before you configure the RSPAN remote-span feature, use the vlan (global configuration) command to
create the VLAN.
Examples This example shows how to configure an RSPAN VLAN:
Switch(config)# vlan 901
Switch(config-vlan)# remote-span
This example shows how to remove the RSPAN feature from a VLAN:
Switch(config)# vlan 901
Switch(config-vlan)# no remote-span
You can verify your settings by entering the show vlan user EXEC command.
Release Modification
12.1(11)EA1 This command was introduced.

Table of Contents

Other manuals for Cisco Catalyst 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2950 and is the answer not in the manual?

Cisco Catalyst 2950 Specifications

General IconGeneral
Forwarding Bandwidth8.8 Gbps
Switching Capacity13.6 Gbps
Forwarding Rate6.6 Mpps
Weight3.6 kg
RAM16 MB
Flash Memory8 MB
Operating Humidity10% to 85% non-condensing
Uplink Ports2 x 10/100/1000Base-T
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Remote Management ProtocolSNMP, Telnet, HTTP
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p
Status Indicatorssystem
Operating Temperature0 to 45°C
Ports24 x 10/100 Ethernet ports
MAC Address Table Size8, 192 entries
Power SupplyInternal 100-240V AC, 50-60Hz