EasyManuals Logo

Cisco Catalyst 2950 Command Reference

Cisco Catalyst 2950
686 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #623 background imageLoading...
Page #623 background image
B-11
Catalyst 2950 and Catalyst 2955 Switch Command Reference
OL-10102-01
Appendix B Catalyst 2950 and 2955 Switch Boot Loader Commands
fsck
fsck
Use the fsck boot loader command to check the file system for consistency.
fsck [-test | -f] filesystem:
Syntax Description
Defaults No file system check is performed.
Command Modes Boot loader
Command History
Usage Guidelines To stop an in-progress file system consistency check, disconnect the switch power and then reconnect
the power.
Examples This example shows how to perform an extensive file system check on flash memory:
switch: fsck -test flash:
-test (Optional) Initialize the file system code and perform extra POST on flash memory.
An extensive, nondestructive memory test is performed on every byte that makes up
the file system.
-f (Optional) Initialize the file system code and perform a fast file consistency check.
Cyclic redundancy checks (CRCs) in the flashfs sectors are not checked.
filesystem: Alias for a flash file system. Use flash: for the system board flash device.
Release Modification
12.1(11)YJ This command was introduced.

Table of Contents

Other manuals for Cisco Catalyst 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2950 and is the answer not in the manual?

Cisco Catalyst 2950 Specifications

General IconGeneral
Forwarding Bandwidth8.8 Gbps
Switching Capacity13.6 Gbps
Forwarding Rate6.6 Mpps
Weight3.6 kg
RAM16 MB
Flash Memory8 MB
Operating Humidity10% to 85% non-condensing
Uplink Ports2 x 10/100/1000Base-T
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Remote Management ProtocolSNMP, Telnet, HTTP
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p
Status Indicatorssystem
Operating Temperature0 to 45°C
Ports24 x 10/100 Ethernet ports
MAC Address Table Size8, 192 entries
Power SupplyInternal 100-240V AC, 50-60Hz