Page #594 background image
A-4
Catalyst 2950 and Catalyst 2955 Switch Command Reference
OL-10102-01
Appendix A Catalyst 2955 Alarm Commands
alarm facility temperature
alarm facility temperature
Use the alarm facility temperature global configuration command to configure a primary temperature
monitoring alarm or to configure a secondary temperature alarm threshold with a lower maximum
temperature threshold. Use the no form of this command to delete the temperature monitoring alarm
configuration or to disable the secondary temperature alarm.
alarm facility temperature {primary {notifies | relay {major | minor} | syslog} | secondary
{threshold | notifies | relay {major | minor}| syslog}}
no alarm facility temperature {primary {notifies | relay {major | minor} | syslog} | secondary
{threshold | notifies | relay {major | minor}| syslog}}
Syntax Description
Defaults The primary temperature alarm is enabled for a -20 to 95
o
C range and cannot be deleted. It is associated
with a major relay. The secondary temperature alarm is disabled by default.
Command Modes Global configuration
Command History
Usage Guidelines The primary temperature alarm is automatically enabled. It cannot be disabled, but you can configure
alarm options.
You can use the secondary temperature alarm to trigger a high temperature alarm at lower than the
maximum primary temperature threshold (95
o
C). You can configure the temperature threshold and alarm
options.
Before you use the notifies keyword to sent alarm traps to an SNMP host, you need to set up an SNMP
server by using the snmp-server enable traps global configuration command.
threshold Set a lower high temperature threshold for the secondary temperature alarm in
degrees C. The allowable range is 40 to 95
o
C.
notifies Send primary or secondary temperature alarm traps to a Simple Network
Management Protocol (SNMP) server.
relay major Send the primary or secondary temperature alarm to the major relay circuitry.
relay minor Send the primary or secondary temperature alarm to the minor relay circuitry.
syslog Send primary or secondary temperature alarm traps to a syslog server.
Release Modification
12.1(12c)EA1 This command was introduced.

Table of Contents

Other manuals for Cisco Catalyst 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2950 and is the answer not in the manual?

Cisco Catalyst 2950 Specifications

General IconGeneral
Forwarding Bandwidth8.8 Gbps
Switching Capacity13.6 Gbps
Forwarding Rate6.6 Mpps
Weight3.6 kg
RAM16 MB
Flash Memory8 MB
Operating Humidity10% to 85% non-condensing
Uplink Ports2 x 10/100/1000Base-T
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Remote Management ProtocolSNMP, Telnet, HTTP
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p
Status Indicatorssystem
Operating Temperature0 to 45°C
Ports24 x 10/100 Ethernet ports
MAC Address Table Size8, 192 entries
Power SupplyInternal 100-240V AC, 50-60Hz

Related product manuals