2-418
Catalyst 2950 and Catalyst 2955 Switch Command Reference
0L-10102-01
Chapter 2 Catalyst 2950 and 2955 Cisco IOS Commands
show vlan
This is an example of output from the show vlan brief command:
Switch> show vlan brief
VLAN Name Status Ports
---- -------------------------------- --------- -------------------------------
1 default active Fa0/1, Fa0/2, Fa0/3, Fa0/4
Fa0/5, Fa0/6
1002 fddi-default active
1003 token-ring-default active
1004 fddinet-default active
1005 trnet-default active
This is an example of output from the show vlan id command. The specified VLAN is in the extended
VLAN range.
Switch# show vlan id 2005
VLAN Name Status Ports
---- -------------------------------- --------- -------------------------------
2005 VLAN 2005 active Fa0/2
VLAN Type SAID MTU Parent RingNo BridgeNo Stp BrdgMode Trans1 Trans2
---- ----- ---------- ----- ------ ------ -------- ---- -------- ------ ------
2005 enet 102005 1500 - - - - - 0 0
This is an example of output from the show vlan summary command:
Switch> show vlan summary
Number of existing VLANs : 7
Number of existing VTP VLANs : 7
Number of existing extended VLANs : 0
Related Commands
Trans1 Translation bridge 1.
Trans2 Translation bridge 2.
AREHops Maximum number of hops for All-Routes Explorer frames—possible values
are 1 through 13; the default is 7.
STEHops Maximum number of hops for Spanning-Tree Explorer frames—possible
values are 1 to 13; the default is 7.
Backup CRF Status of whether or not the Token Ring concentrator relay function (TrCRF)
is a backup path for traffic.
Table 2-31 show vlan Command Output Fields (continued)
Field Description
Command Description
switchport mode Configures the VLAN membership mode of a port.
vlan (global
configuration)
Enables config-vlan mode where you can configure VLANs 1 to 4094.
vlan (VLAN
configuration)
Configures VLAN characteristics in the VLAN database. Only available for
normal-range VLANs (VLAN IDs 1 to 1005).

Table of Contents