EasyManuals Logo

Cisco Catalyst 2950 Command Reference

Cisco Catalyst 2950
686 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #611 background imageLoading...
Page #611 background image
A-21
Catalyst 2950 and Catalyst 2955 Switch Command Reference
OL-10102-01
Appendix A Catalyst 2955 Alarm Commands
test relay
test relay
Use the test relay privileged EXEC command to turn on or off the relay circuitry.
test relay {major | minor} {on| off}
Caution Using the test command alters the state (on or off) of a relay. Previous states are not saved.
Command Modes Privileged EXEC
Command History
Usage Guidelines You can use the test relay privileged EXEC command to check relay circuitry connections to the alert
devices. The command provides a way to test alarm scanners without having to create an alarm
condition.
Examples This example shows how to turn on the major relay circuitry:
Switch# test relay major on
Related Commands
Release Modification
12.1(12c)EA1 This command was introduced.
Command Description
show alarm profile Displays all alarm profiles or a specified alarm profile and lists the
interfaces to which each profile is attached.
show alarm settings Displays environmental alarm settings and options.
show facility-alarm relay Displays alarm relays generated on the switch.

Table of Contents

Other manuals for Cisco Catalyst 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2950 and is the answer not in the manual?

Cisco Catalyst 2950 Specifications

General IconGeneral
Forwarding Bandwidth8.8 Gbps
Switching Capacity13.6 Gbps
Forwarding Rate6.6 Mpps
Weight3.6 kg
RAM16 MB
Flash Memory8 MB
Operating Humidity10% to 85% non-condensing
Uplink Ports2 x 10/100/1000Base-T
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Remote Management ProtocolSNMP, Telnet, HTTP
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p
Status Indicatorssystem
Operating Temperature0 to 45°C
Ports24 x 10/100 Ethernet ports
MAC Address Table Size8, 192 entries
Power SupplyInternal 100-240V AC, 50-60Hz