EasyManua.ls Logo

Cisco Catalyst 2950

Cisco Catalyst 2950
686 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-283
Catalyst 2950 and Catalyst 2955 Switch Command Reference
0L-10102-01
Chapter 2 Catalyst 2950 and 2955 Cisco IOS Commands
show cluster candidates
This is an example of output from the show cluster candidates command that uses the MAC address of
a member switch directly connected to the command switch:
Switch# show cluster candidates mac-address 00d0.7961.c4c0
Device 'c2950-12' with mac address number 00d0.7961.c4c0
Device type: cisco WS-C2950-12
Upstream MAC address: 00d0.796d.2f00 (Cluster Member 0)
Local port: Fa0/3 FEC number:
Upstream port: Fa0/13 FEC Number:
Hops from cluster edge: 1
Hops from command device: 1
This is an example of output from the show cluster candidates command that uses the MAC address of
a member switch three hops from the cluster edge:
Switch# show cluster candidates mac-address 0010.7bb6.1cc0
Device 'c2950-24' with mac address number 0010.7bb6.1cc0
Device type: cisco WS-C2950-24
Upstream MAC address: 0010.7bb6.1cd4
Local port: Fa2/1 FEC number:
Upstream port: Fa0/24 FEC Number:
Hops from cluster edge: 3
Hops from command device: -
This is an example of output from the show cluster candidates detail command:
Switch# show cluster candidates detail
Device 'c2950-12' with mac address number 00d0.7961.c4c0
Device type: cisco WS-C2950-12
Upstream MAC address: 00d0.796d.2f00 (Cluster Member 1)
Local port: Fa0/3 FEC number:
Upstream port: Fa0/13 FEC Number:
Hops from cluster edge: 1
Hops from command device: 2
Device '1900_Switch' with mac address number 00e0.1e7e.be80
Device type: cisco 1900
Upstream MAC address: 00d0.796d.2f00 (Cluster Member 2)
Local port: 3 FEC number: 0
Upstream port: Fa0/11 FEC Number:
Hops from cluster edge: 1
Hops from command device: 2
Device 'c2924-XL' with mac address number 00e0.1e9f.7a00
Device type: cisco WS-C2924-XL
Upstream MAC address: 00d0.796d.2f00 (Cluster Member 3)
Local port: Fa0/5 FEC number:
Upstream port: Fa0/3 FEC Number:
Hops from cluster edge: 1
Hops from command device: 2
Related Commands Command Description
show cluster Displays the cluster status and a summary of the cluster to which the
switch belongs.
show cluster members Displays information about the cluster members.

Table of Contents

Other manuals for Cisco Catalyst 2950

Related product manuals