4-21
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 4 Error Messages
EID-3122 No object of type {0} was selected to edit. Choose an object of the specified type to
edit.
EID-3123 An error occurred while editing {0}. There was an error editing the item.
EID-3124 The {0} termination is in use.
Delete the associated OSPF range table entry and try again.
Refer to the error message text.
EID-3125 No {0} terminations were selected. No specified terminations are selected.
EID-3126 The {0} termination could not be edited. CTC could not edit the specified
termination.
EID-3127 Orderwire cannot be provisioned because the E2 byte is in use
by {0}.
Refer to the error message text.
EID-3128 The authentication key cannot exceed {0} characters. The authentication key cannot exceed the
specified number of characters.
EID-3129 The authentication keys do not match! Refer to the error message text.
EID-3130 An error occurred while creating the OSPF area virtual link. CTC encountered an error while creating
the area virtual link.
EID-3131 An error occurred while creating the OSPF virtual link. CTC encountered an error creating the
virtual link.
EID-3132 An error occurred while setting the OSPF area range: {0}, {1},
false.
CTC encountered an error while setting the
area range for the specified values.
EID-3133 The maximum number of OSPF area ranges has been exceeded. OSPF area ranges exceeded the maximum
number.
EID-3134 The area ID is invalid. Use the DCC OSPF area ID, LAN port
area ID, or 0.0.0.0.
Refer to the error message text.
EID-3135 The mask is invalid. Refer to the error message text.
EID-3136 The range address is invalid. The range address is invalid. Try again.
EID-3137 Your request has been denied because the timing source
information was updated while your changes were still
pending. Please retry.
Refer to the error message text.
EID-3138 The clock source for switching is invalid. You have selected an invalid clock source.
Choose another clock.
EID-3139 A switch cannot be made to a reference of inferior quality. Refer to the error message text.
EID-3140 A higher priority switch is already active. You cannot switch the timing source
manually when a higher priority switch is
already active.
EID-3141 An attempt was made to access a bad reference. Refer to the error message text.
EID-3142 No switch is active. None of the switches are active.
EID-3143 An error occurred while creating the static route entry. CTC encountered an error while a creating
static route entry.
EID-3144 The maximum number of static routes has been exceeded. The number of static routes has exceeded its
limit.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description