Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 4 Error Messages
EID-3235 The requested state transition cannot be performed on this
software version.
Refer to the error message text.
EID-3236 The database restore failed. {0} CTC failed to restore the specified
database.
EID-3237 The database backup failed. {0} CTC failed to backup the specified
database.
EID-3238 The send PDIP setting on {0} is inconsistent with the setting on
the control node {1}.
The send payload defect indicator path
(PDI-P) setting on the specified item should
be consistent with that of the specified
control node.
EID-3239 The overhead termination is invalid Refer to the error message text.
EID-3240 The maximum number of overhead terminations has been
exceeded.
Overhead terminations have exceeded the
limit.
EID-3241 The {0} termination port is in use. The specified termination port is in use.
Select another port.
EID-3242 An {1} exists on the selected ports.
Therefore, you must create the {0}s one by one.
The specified DCC already exists on the
selected port. You can create a DCC of
another type.
WID-3243 The port you have chosen as an {0} endpoint already supports
an {1}. The port cannot support both DCCs. After the {0} is
created, verify that no EOC alarms are present and then delete
the {1} to complete the downgrade.
The same port can not be used by multiple
DCCs.
EID-3244 An {0} exists on the selected ports.
Therefore, you must create the {1}s one by one.
The specified DCC already exists on the
selected port. You can create a DCC of
another type.
WID-3245 The port you have chosen as an {1} endpoint already supports
an {0}. The port cannot support both DCCs. After the {1} is
created, verify that no EOC alarms are present and then delete
the {0} to complete the upgrade.
The port selected as a DCC endpoint
already supports another DCC. Refer to the
warning message text.
EID-3246 The wizard was not able to validate the data.
{0}
CTC encountered an error.
EID-3247 An ordering error occurred. The absolute value should be {0}. The absolute value entered was wrong.
EID-3248 The value for the parameter {0} is invalid. CTC changed the incorrect parameter.
EID-3249 The voltage increment value is invalid. Refer to the error message text.
EID-3250 The power monitor range is invalid. Refer to the error message text.
EID-3251 The requested action could not be completed.
{0}
CTC could not complete the specified
action.
EID-3252 No download has been initiated from this CTC session. Refer to the error message text.
EID-3253 The reboot operation failed. {0} Refer to the error message text.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description