4-29
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 4 Error Messages
EID-3315 This operation cannot be performed. CTC is unable to perform operation.
EID-3316 The node side is invalid. This task was applied to the wrong node
side.
EID-3317 The ring name is too long. Reduce the number of characters in the
name.
EID-3318 The ring name is invalid. The name you entered is illegal.
EID-3319 The wrong line was selected. Select another line
EID-3320 The optical link could not be deleted. CTC cannot delete the optical link.
EID-3321 This feature is unsupported by this version of software. Refer to the error message text.
EID-3322 The equipment is not plugged in. Plug-in the equipment and proceed.
EID-3323 The APC system is busy. Automatic Power Control (APC) system is
busy.
EID-3324 There is no path to regulate. There is no circuit path to regulate.
EID-3325 The requested action is not allowed. Generic DWDM provisioning failure
message.
EID-3326 The input was invalid. The input value is incorrect.
EID-3327 An error occurred while retrieving thresholds. There was an error retrieving the thresholds.
This message is displayed only for the
OSCM/OSC-CSM line thresholds.
EID-3328 An error occurred while applying changes to row {0}.
The value is out of range.
There was an error applying the changes to
the specified row. The value is out of range.
EID-3330 Unable to switch to the byte because an overhead channel is
present on this byte of the port.
Refer to the error message text.
EID-3331 An error occurred while applying changes to the row. Refer to the error message text.
EID-3334 Timing parameters on the protect port cannot be changed. You cannot change timing parameters on
protect port.
EID-3335 The port type cannot be changed because the SDH validation
check failed. Check if this port is part of a circuit, protection
group, SONET DCC, orderwire, or UNI-C interface.
Refer to the error message text.
EID-3336 An error occurred while reading a control mode value. The Control Mode must be retrieved.
EID-3337 An error occurred while setting a set point gain value. The Gain Set Point must be set.
EID-3338 An error occurred while reading a set-point gain value. The Gain Set Point must be retrieved.
EID-3339 An error occurred while setting a tilt calibration value. The tilt calibration must be set.
EID-3340 An error occurred while setting expected wavelength. The expected wavelength must be set.
EID-3341 An error occurred while reading expected wavelength. The expected wavelength must be retrieved.
EID-3342 An error occurred while reading actual wavelength. The actual wavelength must be retrieved.
EID-3343 An error occurred while reading actual band. The actual band must be retrieved.
EID-3344 An error occurred while reading expected band. The expected band must be retrieved.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description