4-34
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 4 Error Messages
WID-5006 Warning: A different secondary {0} node should only be used
for DRI or open-ended path protected circuits.
You should use different secondary end
point only for DRI or open-ended path
protected circuits.
WID-5007 If you change the scope of this view, the contents of this profile
editor will be lost.
Refer to the warning message text.
WID-5008 Please ensure that all the protection groups are in proper states
after the cancellation.
Refer to the warning message text.
WID-5009 The circuit {0} is not upgradable.
No {1} capable {2}s are available at the node {3}.
No VT capable STSs are available at the
node.
EID-5010 The domain name already exists. Refer to the error message text.
EID-5011 The domain name cannot exceed {0} characters. You may have reached the maximum
number of characters.
WID-5012 The software load on {0} does not support the addition of a
node to a 1+1 protection group.
Refer to the warning message text.
EID-5013 {0} does not support the bridge and roll feature. Please select a
different port.
The specified port does not support Bridge
and Roll.
EID-5014 An automatic network layout is already in progress.
Please wait for it to complete before running it again.
You must for the automatic network layout
to complete before running it again.
WID-5015 {0} cannot be applied to {1}. You cannot apply the admin state operation,
specified by {0}, to port count, specified by
{1}.
EID-5016 An error occurred while attempting to provision the {0}.
{1}
CTC encountered an error while
provisioning the card.
EID-5017 Provisioning could not be rolled back. The {0} might be left in
an INCOMPLETE state and should be manually removed.
You may have to remove the BLSR
manually as it was left incomplete.
EID-5018 {0} is a(n) {1} node and cannot be added to a(n) {2} network. You cannot add the node {0} of type {1} to
the host node of type {2}. This prevents you
from hosting both SONET and SDH nodes
in the same session.
EID-5019 The manual path trace mode for this equipment does not
support an expected string consisting of all null characters.
Please change the expected string or the path trace mode.
The path trace mode does not support
strings that consist of null characters. You
must either change the expected string or
the path trace mode.
EID-5020 Software activation is in progress. Provisioning is not allowed. Refer to the warning message text.
EID-5021 Software activation is in progress. {0} is not allowed. Refer to the error message text.
WID-5022 Warning: Ethergroup circuits are stateless (that is, always in
service).
The current state selection of {0} will be ignored.
Refer to the warning message text.
EID-5023 CTC cannot communicate with the node.
The operation failed.
CTC encountered a network
communication error. Connectivity between
CTC and the NE was disrupted, either
transiently or permanently.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description