4-35
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 4 Error Messages
EID-5024 The overhead circuit will not be upgraded. Refer to the error message text.
WID-5025 The path targeted for this switch request is already active. The
switch request can be applied, but traffic will not switch at this
time.
Refer to the warning message text.
EID-5026 An ONS 15600 cannot serve as the primary or secondary node
in a four-fiber {0} circuit. Please change your ring and/or node
selections so that an ONS 15600 is not chosen as the primary or
secondary node in this four-fiber {1} circuit.
Refer to the error message text.
WID-5027 The {0} Edit dialog box for the ring {1} has been closed due to
significant provisioning changes. These changes might only be
transitory, so you can reopen the {0} Edit dialog box to view the
updated state.
Re-open the BLSR/MS-SPRing edit
window to view the updated state of the
ring.
WID-5028 Warning: This operation should only be used to clean up rolls
that are stuck. It might also affect completeness of the circuit.
Is it OK to continue with the deletion?
Refer to the warning message text.
EID-5029 A software downgrade cannot be performed to the selected
version while an SSXC card is inserted in this shelf. Please
follow the steps to replace the SSXC with a CXC card before
continuing the software downgrade.
Refer to the error message text.
EID-5030 A software downgrade cannot be performed at the present time. Try the software downgrade later.
WID-5031 Canceling a software upgrade during a standby TSC clock
acquisition might result in a traffic outage.
Refer to the warning message text.
EID-5032 An error occurred while accepting the load. Refer to the error message text.
EID-5033 The profile could not be loaded.
An error occurred while decoding the characters.
CTC detected an error while decoding
characters and could not load the profile.
EID-5034 The profile could not be loaded.
An error occurred while trying to recognize the file format.
CTC detected an error and could not load
the profile.
EID-5035 The profile could not be loaded.
An error occurred while reading the file.
CTC could not read the file and is therefore
unable to load the profile.
EID-5036 The GNE hostname {0} is invalid. The specified host name is invalid. CTC
could not resolve the host name to any valid
IP address
EID-5037 Provisionable patchcords cannot be created between
transponder trunk ports and multiplexer/demultiplexer ports on
the same node.
You must create provisionable patchcords
between transponder trunk ports and
mux/demux ports that are on different
nodes.
EID-5038 Provisionable patchcords created between transponder trunk
ports and multiplexer/demultiplexer ports must use the same
wavelength:
{0} is not equal to {1}.
Wavelengths used by provisionable
patchcords for transponder trunk ports and
mux/demux ports must be the same.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description