4-36
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 4 Error Messages
EID-5039 Provisionable patchcords created between transponder trunk
ports and multiplexer/demultiplexer ports must use the same
wavelength:
{0} is not equal to {1}.
Please provision the {2} wavelength on {3}.
Transmitter and receiver port wavelengths
are not equal. Provision the receiver and
transmitter wavelengths on transmitter and
receiver ports respectively.
EID-5040 Provisionable patchcords created between OC3/OC12 ports and
multiplexer/demultiplexer ports are not supported.
Refer to the error message text.
EID-5041 Provisionable patchcords created between gray OC-N trunk
ports and multiplexer/demultiplexer ports are not supported.
Refer to the error message text.
EID-5042 Provisionable patchcords created between OC-N trunk ports
and multiplexer/demultiplexer ports must use the same
wavelength:
{0} is not equal to {1}.
Wavelengths used by provisionable
patchcords for OC-N trunk ports and
mux/demux ports must be the same.
WID-5043 Warning: Only the line card was provisioned.
The wavelength compatibility check was skipped.
Refer to the warning message text.
EID-5044 Virtual links can be used only for OCH-Trail circuits. Refer to the error message text.
EID-5045 The virtual link does not have wavelengths available. Set wavelengths for the virtual link and
proceed.
WID-5046 Warning: if you select "Use OCHNC Direction," your circuit
will be limited to nodes prior to release 07.00.
Refer to the warning message text.
EID-5047 Provisionable patchcords created between OC3/OC12 ports are
not supported.
Refer to the error message text.
EID-5048 Provisionable patchcords created between gray OC-N trunk
ports are not supported.
Refer to the error message text.
EID-5049 Provisionable patchcords created between gray OC-N trunk
ports and multiplexer/demultiplexer ports are not supported.
Refer to the error message text.
EID-5050 The element model could not be found.
{0}
The specified Element Model cannot be
located.
WID-5051 The port state cannot be indirectly transitioned because the port
aggregates OCHCC circuits: if the port state needs to be
changed, edit it directly through port provisioning.
Refer to the warning message text.
EID-5052 The operation is not valid for the connection type. You may have selected the incorrect switch.
EID-5053 The operation cannot be performed because the connection is
under test access.
Refer to the error message text.
EID-5054 The TL1 tunnel could not be opened. {0} Refer to the error message text.
EID-5055 Some patchcords were not deleted. Patchcords cannot be
deleted if they are incomplete or support any circuits, or if the
nodes supporting them are not connected.
Refer to the error message text.
EID-5056 This PPC cannot be deleted because one or more circuits are
provisioned over it.
Remove the circuits provisioned over the
provisionable patchcord before trying to
delete it.