Product Manual — Doc. 9045M DM NAX® • 232
streams enable control of the audio signal to third-party uncontrolled AES67 devices receiving audio
from the DM-NAX-8ZSA.
NOTES:
l
Under the Transmitters section (see Configure Transmitters), the last four listed transmitters
are dedicated to parallel zone outputs.
l
To configure the DSP settings, see Zone Settings.
Click NAXStreams to expand the tab and display the following information.
l
Device is Master PTP Clock Source indicates whether the DMNAX device's PTP clock is the master
clock on the network. Yes will be displayed in green when the local DM-NAX-8ZSA's clock is the
PTP master clock and No will be displayed in red when another PTP clock on the network is
operating as the master clock.
l
Master Clock Status displays the Master Clock ID of the device on the network that is currently
acting as the master clock.
l
PTP Priority: This sets the priority of the local DMNAX device's PTP clock relative to other clocks
on the network. The default setting is 254 (one increment higher than the lowest possible value)
so that the DM-NAX-8ZSA will only operate as clock master if no other PTP master is present on
the network. Valid values range from 1 to 255.