Product Manual — Doc. 9045M DM NAX® • 392
DM NAX Streams
Each local input of the DM-NAX-8ZSA can be made available as a DMNAX audio-over-IP stream.
Click NAXStreams to display the following information.
l
Device is Master PTP Clock Source indicates whether the device is the master for PTP on the
network. Yes will be displayed in green when the local DM-NAX-16AIN is the PTP clock master and
No will be displayed in red when another PTP clock on the network is operating as the master
clock.
l
Master Clock Status displays the Master Clock ID of the device on the network that acts as the
Master Clock.
l
PTP Priority: This sets the priority of the local DMNAX device's PTP clock relative to other clocks
on the network. The default setting is 254 (one increment higher than the lowest possible value)
so that the DM-NAX-16AIN will only operate as clock master if no other PTP master is present on
the network. Valid values range from 1 to 255.