xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
1352
the value should be recovered fromor exceeded
thesholdSubType: the DDM threshold sub type, the value should
be highor low”.
Event description: DDM exceeded or recover from DDM warning
threshold
Log Message: DDM Port <[unitID:]portNum> optic module
[thresholdType] [exceedType] the [thresholdSubType] warning
threshold
Parameters description:
unitID: The unit ID.
portNum: The port number.
thresholdType: the DDM threshold type. The value should be one
of the following values: temperature, supply voltage, bias current,
TX power, RX power.
exceedType: indicate exceed threshold or recover to normal event,
the value should be recovered fromor exceeded
thesholdSubType: the DDM threshold sub type, the value should
be highor low.
Warning
BPDU
Event description: BPDU attack happened.
Log Message: Port<[unitID:]portNum> enter BPDU under
protection state (mode: drop / block / shutdown)
Parameters description:
unitID: The unit ID.
portNum: The port number.
mode:The BPDU currnt state
Informational
Event description: BPDU attack automatically recover.
Log Message: Port <[unitID:]portNum> recover from BPDU under
protection state automatically
Parameters description:
unitID: The unit ID.
portNum: The port number.
Informational
Event description: BPDU attack manually recover.
Log Message: Port<[unitID:]portNum> recover from BPDU under
protection state automatically
Parameters description:
unitID: The unit ID.
portNum: The port number.
Informational
External Alarm
Event description: External alarm occurred
Log Message: [Unit <unitID>] External Alarm Channel
<channel_id> : <alarm_message>
Parameters description:
unitID: The unit ID.
channel_id: Represent the channel ID detected the external alarm
alarm_message: Alarm message when alarm occurred, this is
configurable by user.
The default alarm message is defined in “Default Setting” Chapter.
Critical
Event description: External alarm occurred
Log Message: External Alarm Channel <channel_id> :
<alarm_message>
Parameters description:
channel_id: Represent the channel ID detected the external alarm
alarm_message: Alarm message when alarm occurred, this is
configured by the user.
RIPng
Event description: The RIPng state of interface changed
Log Message: RIPng protocol on interface <intf-name> changed
state to <Enabled | Disabled>
Parameters description:
intf-name: Interface name.
Informational
SSH
Event description: Successfully download client public keys.
Log Message: SSH client public keys file was upgraded
successfully (Username: <username>, IP: < ipaddr | ipv6address
>)
Parameters description:
username: The username upgraded client public keys file.
ipaddr: Represent client IP address.
ipv6address: Represent client IP address.
Informational
Peripherals
Event description: Right Side Recovered.
Log Message: Unit <id>, Right Side Fan <id> recovered.
Critical

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link xStack DGS-3620 Series and is the answer not in the manual?

D-Link xStack DGS-3620 Series Specifications

General IconGeneral
BrandD-Link
ModelxStack DGS-3620 Series
CategorySwitch
LanguageEnglish

Related product manuals