EasyManua.ls Logo

D-Link xStack DGS-3620 Series - Page 453

D-Link xStack DGS-3620 Series
1371 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
448
DGS-3620-28PC:admin#config ddm log enable
Command: config ddm log enable
Success.
DGS-3620-28PC:admin#
To configure DDM trap state to enable:
DGS-3620-28PC:admin#config ddm trap enable
Command: config ddm trap enable
Success.
DGS-3620-28PC:admin#
27-2 config ddm ports
Description
The command is used to configure the DDM settings of the specified ports.
Format
config ddm ports [<portlist> | all] [[temperature_threshold {high_alarm <degrees> |
low_alarm <degrees> | high_warning <degrees> | low_warning <degrees>} |
voltage_threshold {high_alarm <voltage> | low_alarm <voltage> | high_warning <voltage> |
low_warning <voltage>} | bias_current_threshold {high_alarm <milliampere> | low_alarm
<milliampere> | high_warning <milliampere> | low_warning <milliampere>} |
tx_power_threshold {high_alarm <mw_or_dbm> | low_alarm <mw_or_dbm> | high_warning
<mw_or_dbm> | low_warning <mw_or_dbm>} | rx_power_threshold {high_alarm
<mw_or_dbm> | low_alarm <mw_or_dbm> | high_warning <mw_or_dbm> | low_warning
<mw_or_dbm>}] | {state [enable | disable] | shutdown [alarm | warning | none]}]
Parameters
<portlist> - Enter the range of ports to be configured here.
all - Specifies that all the optic ports’ operating parameters will be configured.
temperature_threshold - Specifies the threshold of the optic module’s temperature in
centigrade. At least one parameter shall be specified for this threshold.
high_alarm - (Optional) Specifies the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<degrees> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specifies the low threshold for the alarm. When the operating
parameter falls below this value, the action associated with the alarm is taken.
<degrees> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specifies the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<degrees> - Enter the high threshold warning value here.
low_warning - (Optional) Specifies the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<degrees> - Enter the low threshold warning value here.
voltage_threshold - Specifies the threshold of optic module’s voltage.
high_alarm - (Optional) Specifies the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.

Table of Contents

Related product manuals