xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
449
<voltage> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specifies the low threshold for the alarm. When the operating
parameter falls below this value, the action associated with the alarm is taken.
<voltage> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specifies the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<voltage> - Enter the high threshold warning value here.
low_warning - (Optional) Specifies the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<voltage> - Enter the low threshold warning value here.
bias_current_threshold - Specifies the threshold of the optic module’s bias current.
high_alarm - (Optional) Specifies the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<milliampere> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specifies the low threshold for the alarm. When the operating
parameter falls below this value, the action associated with the alarm is taken.
<milliampere> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specifies the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<milliampere> - Enter the high threshold warning value here.
low_warning - (Optional) Specifies the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<milliampere> - Enter the low threshold warning value here.
tx_power_threshold - Specifies the threshold of the optic module’s output power.
high_alarm - (Optional) Specifies the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specifies the low threshold for the alarm. When the operating
parameter falls below this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specifies the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the high threshold warning value here.
low_warning - (Optional) Specifies the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the low threshold warning value here.
rx_power_threshold - Specifies the threshold of optic module’s received power.
high_alarm - (Optional) Specifies the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specifies the low threshold for the alarm. When the operating
parameter falls below this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specifies the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the high threshold warning value here.
low_warning - (Optional) Specifies the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the low threshold warning value here.
state - (Optional) Specifies the DDM state to enable or disable. If the state is disabled, no DDM
action will take effect.
enable - Specifies to enable the DDM state.
disable - Specifies to disable the DDM state.
shutdown - (Optional) Specifies whether or not to shutdown the port when the operating
parameter exceeds the corresponding alarm threshold or warning threshold.
alarm - Shutdown the port when the configured alarm threshold range is exceeded.
warning - Shutdown the port when the configured warning threshold range is exceeded.
none - The port will never shutdown regardless if the threshold ranges are exceeded or not.