xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
748
Format
config loopdetect trap [none | loop_detected | loop_cleared | both]
Parameters
none - Trap will not be sent for both cases.
loop_detected - Trap is sent when the loop condition is detected
loop_cleared - Trap is sent when the loop condition is cleared.
both - Trap will be sent for both cases.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To configure a trap:
DGS-3620-28PC:admin#config loopdetect trap both
Command: config loopdetect trap both
Success.
DGS-3620-28PC:admin#
62-1 config loopdetect log state
Description
This command is used to configure the log state for LBD. The default value is enabled.
Format
config loopdetect log state [enable | disable]
Parameters
state - Specifies the LBD log feature's state.
enable - Specifies that the LBD log feature will be enabled.
disable - Specifies that the LBD log feature will be disabled.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To enable the log state for LBD:
DGS-3620-28PC:admin# config loopdetect log state enable
Command: config loopdetect log state enable

Table of Contents